Parameter | Value |
---|---|
MAXIMUM LOAD [kg] | 600 |
MAXIMUM WIRE DIAMETER [mm] | 8 |
MAXIMUM LINEAR SPEED [m/min] | 1700 |
MAXIMUM CONSTANT TENSION [N] | 200 |
MOTOR POWER [kw] | 2 x 15 |
SPOOL WIDTH [mm] | MIN. 250 | MAX. 550 |
SPOOL OUTER DIAMETER [mm] | MIN. 360 | MAX. 630 AND NPS D400 |
MINIMUM INNER DIAMETER [mm] | 200 |
DIMENSIONS (L x W x H) [m] | 2,6 x 2,2 x 2,0 |
Parameter | Value |
---|---|
MAXIMUM LOAD [kg] | 1000 |
MAXIMUM WIRE DIAMETER [mm] | 10 |
MAXIMUM LINEAR SPEED [m/min] | 1600 |
MAXIMUM CONSTANT TENSION [N] | 200 |
MOTOR POWER [kw] | 2 x18,5 |
SPOOL WIDTH [mm] | MIN. 250 | MAX. 600 |
SPOOL OUTER DIAMETER [mm] | MIN. 400 | MAX. 800 and NPS D400 |
MINIMUM INNER DIAMETER [mm] | 250 |
DIMENSIONS (L x W x H) [m] | 2,8 x 2,3 x 2,2 |
Parameter | Value |
---|---|
MAXIMUM LOAD [kg] | 1500 |
MAXIMUM WIRE DIAMETER [mm] | 15 |
MAXIMUM LINEAR SPEED [m/min] | 1500 |
MAXIMUM CONSTANT TENSION [N] | 300 |
MOTOR POWER [kw] | 2 x 22 |
SPOOL WIDTH [mm] | MIN. 350 | MAX. 750 |
SPOOL OUTER DIAMETER [mm] | MIN. 630 | MAX. 1000 AND NPS D400 |
MINIMUM INNER DIAMETER [mm] | 300 |
DIMENSIONS (L x W x H) [m] | 3,0 x 2,35 x 2,3 |
Parameter | Value |
---|---|
MAXIMUM LOAD [kg] | 2000 |
MAXIMUM WIRE DIAMETER [mm] | 20 |
MAXIMUM LINEAR SPEED [m/min] | 1300 |
MAXIMUM CONSTANT TENSION [N] | 350 |
MOTOR POWER [kw] | 2 x30 |
SPOOL WIDTH [mm] | MIN. 400 | MAX. 1100 |
SPOOL OUTER DIAMETER [mm] | MIN. 630 | MAX. 1250 |
MINIMUM INNER DIAMETER [mm] | 300 |
DIMENSIONS (L x W x H) [m] | 3,4 x 2,4 x 2,4 |